MYOPIYA MAVJUD BO`LGAN BEMORLARDA CORVIS ST JIHOZIDAN FOYDALANISHNING SAMARADORLIGI VA IMKONIYATLARI TAHLILI
DOI:
https://doi.org/10.57231/j.ao.2025.14.3.009Ключевые слова:
myopiya, shox parda, shox parda biomexanik ko`rsatkichi, shox parda markaziy qalinligi, ko`z ichi bosimiАннотация
Dolzarbligi. Shox parda murakkab biomexanik tuzilishga ega bo’lgan a`zodir. Unga ta`isr etuvchi tashqi omillar natijasida o`z egriligini o`zgartiradi hamda ma`lum bir darajada qarshilik ko`rsatadi. Aynan shu hususiyatidan foydalangan holda shox parda biomexanik ko`rsatkichlarini zamonaviy jihoz yordamida o`rganish ilmiy-amaliy ahamiyatga egadir. Tadqiqot maqsadi. Turli darajadagi myopiya mavjud bo`lgan bemorlarda Corvis ST jihozi yordamida shox pardaning biomexanik xususiyatlari hamda shox parda biomexanik ko`rsatkichlarini baholashdir. Material va usullar. 2025 yil yanvar va sentyabr oylari mobaynida murojaat qilgan turli darajada myopiyasi mavjud bo`lgan jami 78 ta bemorning (125 ta ko`zi) da Corvis ST jihozidan foydalanib shox pardaning biomexanik ko`rsatkichlari o`rganildi. Barcha bemorlarda kerakli umumiy va maxsus oftalmologik tekshiruvlar o`tkazildi. Shox parda biomexanik ko`rsatkichidan tashqari ko`z olmasining aksiyal o`qi uzunligi, shox parda markaziy qalinligi, biomexanik ko`z ichi bosimi hamda bemorlarning ko`ruv o`tkirligi tahlil qilindi. Natijalar va xulosa. Yengil darajali myopiya mavjud bo`lgan bemorlarga qaraganda yuqori darajali hamda shox parda markaziy qalinligi yupqa bo`lgan bemorlarda shox parda biomexanik o`lchamlarining asosiy ko`rsatkichlarida ortish tendentsiyasi aniqlanmoqda.
Библиографические ссылки
Huseynova T, Waring GO, Roberts C, Krueger RR, Tomita M. Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes. Am J Ophthalmol 2014;157:885-893
Pinero DP, Alcon N. In vivo characterization of corneal biomechanics. J Cataract Refractive Surg 2014;40:870-887
Hassan Z, Modis L, Jr, Szalai E, Berta A, Nemeth G. Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery. Cont Lens Anterior Eye 2014;37:337-341
Hong J, Xu J, Wei A, Deng SX, Cui X, Yu X, et al. A new tonometer-the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci 2013;54:659-665
Tian L, Huang YF, Wang LQ, Bai H, Wang Q, Jiang JJ et al. Corneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes. J Ophthalmol 2014;2014:147516
Valibon BF, Ambrosio R, Jr, Fontes BM, Luz A, Roberts CJ, Alves MR. Ocular biomechanical metrics by Corvis ST in healthy Brazillian patients. J Refractive Surg 2014;30:468-473